Blood Pressure Meter 08A with Spo2 Probe & adaptor
This is a desktop Electronic Sphygmomanometer,High-definition color LCD display,supply English/Chinese interface,Strong visibility.Fully automatic blood pressure measure,it can be a household sphygmomanometer which is used for adult, pediatric and neonatal.The device has the function of parameter measure,display and record output,and adopt data review interface such as “data list”, “trend chart”, “big font”,with SpO2 measure function(with optional SpO2 probe).It can be applied to the clinique,physical center and daily health care of family member.
Contec-08A Digital Blood Pressure Monitor with SpO2
The popular Contec-08A Professional Digital Blood Pressure Monitor/Electronic Sphygmomanometer includes all the functions required to measure blood pressure, heart rate, and blood oxygen saturation levels. This blood pressure machine automatically inflates the blood pressure cuff attachment and displays measurements on the color TFT screen. Blood pressure cuffs and probes for this blood pressure monitor are available in adult, child, infant, and newborn options.
The Contec-08A tests Systolic Pressure, Diastolic Pressure, and MAP Pressure. Programmable alarms alert to upper/lower limit threshold readings for Systolic and Diastolic values. This monitor also includes a low power indicator and auto power-off function.
The front-facing buttons control navigation of the monitor’s intuitive on-screen menus. Testing procedures are available within the menus for adult, pediatric, and neonatal test options. Each setting configuration will set the Contec-08A’s blood pressure cuff to the appropriate amount of pressure for each individual during the test. The blood pressure cuff automatically inflates with one press of the “START/STOP” button.
The Contec-08A can store blood pressure information for up to three users. Built-in storage in the device holds up to 99 readings per user (the monitor overwrites the oldest data after reaching storage capacity). The data can be reviewed, analyzed, graphed, and printed using the included software. A data transfer cable connects the unit to a computer via USB.
The CMS-08A Professional Digital Blood Pressure Monitor includes a USB cable, charging adapter, charging cable, SpO2 probe sensor, instruction manual, and blood pressure cuff.
Blood Pressure Meter 08A with Spo2 Probe & adaptor
What’s Included in Package
- CMS-08A Blood Pressure Monitor
- Adult Auto-inflate Blood Pressure Cuff (See Optional Cuffs)
- Adult SpO2 Probe Sensor (See Optional Probes)
- USB Cable
- User Manual
- Wall Power Adaptor
- Charging Cable
Main Features
- Fully automatic one touch auto-inflation
- High resolution TFT color display
- Memory storage for three user with space for 99 records each
- Programmable alarms for Systolic and Diastolic values
- Low power indicator and auto power off
- USB cable for transferring BP data to a computer
- Cuff selection for Adult, Pediatric, or Neonatal (See Optional Cuffs)
- SPO2 sensors for Adult, Pediatric, and Neonatal applications (See Optional Probes)
- Software included for advanced data analysis, report printing, and trend graphing
Extended Specifications
SpO2 Measurement Range: 35% – 100% |
SpO2 Resolution: 1% |
SpO2 Accuracy: 70% – 100% (±)2%, 0% -69% unspecified |
SpO2 Alarm Range: 25% – 100% |
Pulse Rate Range: 30bpm ~ 254bpm |
Pulse Rate Resolution: 1bpm |
Pulse Rate Accuracy: 1bpm |
Pulse Rate Measuring Range: ±2%bpm |
Measurement Method: Oscillometric Method |
Measurement Working Mode: Automatic |
Measurement Unit: mmHg/kPa selectable |
Measurement Type: SYS/DIA/MAP (Systolic Pressure/Diastolic Pressure/MAP Pressure) |
Measurement Unit: mmHg/kPa selectable |
Measurement Range (Adult): 0 – 290mmHg (0 – 38.6kPa) |
Measurement Range (Pediatric): 0 – 235mmHg (0 – 331.3kPa) |
Measurement Range (Neonatal): 0 – 140mmHg (0 – 18.6kPa) |
Measurement Performance in Weak Filling Conditions (Pulse-Filling Ratio): 0.4% |
Measurement Performance in Weak Filling Conditions (SpO2 Error): ±4% |
Measurement Performance in Weak Filling Conditions (Pulse Rate Error): ±2bpm or ±2% (select larger) |
Optical Sensor Red Light: Wavelength is 660nm, 6.65mW |
Optical Sensor Infrared: Wavelength is 880nm, 6.75mW |
Inflation (Adult): 160mmHg |
Inflation (Pediatric): 120mmHg |
Inflation (Neonatal): 70mmHg |
Alarm Range (Adult Mode): SYS ALM: 40 – 270mmHg, DIA ALM: 10 – 215mmHg |
Alarm Range (Pediatric Mode): 40 – 200mmHg, DIA ALM: 10 – 150mmHg |
Alarm Range (Neonatal Mode): 40 – 135mmHg, DIA ALM: 10 – 100mmHg |
Overpressure Protection (Adult Mode): 295±5mmHg |
Overpressure Protection (Pediatric Mode): 240±5mmHg |
Overpressure Protection (Neonatal Mode): 145±5mmHg |
Pressure Resolution: 1mmHg |
Error Resolution: The BP Value of the device is equivalent with the measurement value of stethoscope. The error meets all the conditions on the ANSI/AAMI SP – 10:2002+A1:2003+A2:2006 |
Cuff Pressure Accuracy: ±3mmHg |
Operating Temperature/Humidity: 5°C – 40°C / 15%RH – 80%RH |
Transport/Storage Temperature/Humidity: -20°C – 55°C / less than or equal to 95%RH |
Atmospheric Pressure: 80kPa – 105kPa |
Display Type: 2.8″ Color LCD Display |
Main Unit Dimensions: 130mm(L)X110mm(W)X80mm(H) |
Main Unit Weight: 300g or 11.2oz |
Battery: AA Alkaline batteries, AC power adaptor included |
AC Adaptor: 300g or 11.2ozInput: AC 100 – 240V 50 – 60Hz AC 500mA, Output: DC 6.0V – ±0.2V 1.0A |
Water Protection Rating: IPX0 |
Safety Class: Type BF |
Software Operating Requirements:
Pentium IV1.8G or more |
Operating System: Windows XP |
EMS Memory: 256M or more |
Hard Disk: 40GB or more |
Display: 17 inch or more |